FL MC EF 1300 MM ST - FO converters

FO converter with B-FOC (ST®) fiber optic connection (1300nm), for converting 10/100Base-T(X) to multi-mode fiberglass (50/125 µm). Auto negotiation and auto MDI(X) function. Comprehensive link diagnostics. DIN-rail mountable, 18 ... 30 V DC supply.
Product Code: 2902854
Partner cod.: 2902854
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Utilization restriction​
CCCex note: Use in potentially explosive areas is not permitted in China.
Product propertiesProduct type: Media converter
MTTF: 1400 Years (SN29500 standard, temperature25°C, operating cycle21%)
599 Years (SN29500 standard, temperature40°C, operating cycle34.25%)
101 Years (SN29500 standard, temperature40°C, operating cycle100%)
MTBF: 492 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))
132 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day))
Signal delay: ± 1.3 µs (Store and Forward mode, 10/100 Mbps, depending on the frame size)
System propertiesFunctionality
Basic functions: Store-and-forward media converter
Electrical propertiesElectrical isolation: according to IEEE 802.3
VCC // FE // Ethernet
Maximum power dissipation for nominal condition: 2.4 W
Test voltage data interface/power supply: 0.5 kVrms (50Hz, 1min.)
Supply
Supply voltage range: 18 VDC ... 30 VDC (Screw connection)
18 VDC ... 30 VDC (as an alternative or redundant, via backplane bus contact and system current supply)
Typical current consumption: < 100 mA (24VDC)
Protective circuit: Reverse polarity protection
Connection dataSupply
Connection method: Plug-in screw terminal block (COMBICON), redundancy possible
Single conductor/terminal point, rigid: 0.2 mm² ... 2.5 mm²
Single-wire/terminal point, flexible: 0.2 mm² ... 2.5 mm²
Conductor cross section, flexible [AWG]: 24 ... 14
Tightening torque: 0.56 Nm ... 0.79 Nm
InterfacesSignal: Ethernet
Basic functions: Store-and-forward media converter
Data: optical FO
Transmit capacity, minimum: ≥ -23.5 dBm ((50/125µm) dynamic in link mode (average))
≥ -20 dBm ((62,5/125µm) dynamic in link mode (average))
Transmit capacity, maximum: ≤ -14 dBm ((50/125µm) dynamic in link mode (average))
≤ -14 dBm ((62,5/125µm) dynamic in link mode (average))
Transmission length incl. 3 dB system reserve: 6.4 km (F-G 50/125 0.7dB/km F 1000)
2.8 km (F-G 50/125 1.6dB/km F 800)
10 km (F-G 62.5/125 0.7dB/km F 1000)
3 km (F-G 62.5/125 2.6dB/km F 600)
Connection method: B-FOC (ST®)
Wavelength: 1300 nm
Minimum receiver sensitivity: -31 dBm (dynamic in link mode (average))
Maximum receiver sensitivity: -14 dBm (dynamic in link mode (average))
Transmission medium: Multi-mode fiberglass
GI-HCS fiber
Data: Ethernet interface, 10/100Base-T(X) in accordance with IEEE 802.3
Transmission speed: 10/100 Mbps
Connection method: RJ45 jack, shielded
No. of channels: 1
Transmission length: 100 m (shielded twisted pair)
Transmission medium: Copper
Signal LEDs: Activity, link status, 10/100 Mbps
Auto-negotiation modes: Auto
Link through: Link fault pass through
MDI-/MDI-X switchover: Auto-MDI(X)
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/7d7eb39588dfce47adda013351adcd19/-S204x204-FJPG
Width: 22.5 mm
Height: 99 mm
Depth: 114.5 mm
Material specificationsMaterial: PA 6.6-FR
Cable/lineFO cable
Fiber types: 50/125 µm
62.5/125 µm
Fiberglass
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -40°C ... 65°C
Ambient temperature (storage/transport): -40°C ... 85°C
Altitude: ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation)
≤ 2000 m (in acc. with UL)
Permissible humidity (operation): 5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport): 5 % ... 95 % (non-condensing)
ApprovalsCE
Certificate: CE-compliant
EAC
Identification: EAC
ATEX
Identification:  II 3 G Ex nA IIC T4 Gc X
Note: Please follow the special installation instructions in the documentation!
ATEX, FO interface
Identification:  II (2) D [Ex op is Db] IIIC
 II (2) G [Ex op is Gb] IIC
Certificate: PTB06ATEX2042U
Note: Please follow the special installation instructions in the documentation!
UL, USA/Canada
Identification: 508 Listed
Class I, Zone 2, AEx nA IIC T4
Class I, Zone 2, Ex nA IIC T4 Gc X
Class I, Div. 2, Groups A, B, C, D
KC approval for South Korea
Certificate: MSIP-REI-PCK-2902854
Corrosive gas test
Identification: ISA-S71.04-1985 G3 Harsh Group A
Shipbuilding
Identification: DNV GL
DNV GL data
Temperature: B
Humidity: A
Vibration: A
EMC: B
Enclosure: Required protection according to the Rules shall be provided upon installation on board
EMC dataElectromagnetic compatibility: Conformance with EMC Directive 2014/30/EU
Electrostatic discharge
Standards/regulations: EN61000-4-2
Electrostatic discharge​
Contact discharge: ± 6 kV (Test Level 3)
Discharge in air: ± 8 kV (Test Level 3)
Indirect discharge: ± 6 kV
Comments: Criterion B
Electromagnetic HF field
Standards/regulations: EN61000-4-3
Electromagnetic HF field​
Frequency range: 80 MHz ... 3 GHz (Test Level 3)
Field intensity: 10 V/m
Comments: Criterion A
Fast transients (burst)
Standards/regulations: EN61000-4-4
Fast transients (burst)​
Input: ± 2 kV (Test Level 3)
Signal: ± 2 kV (Test Level 3)
Comments: Criterion B
Surge current load (surge)
Standards/regulations: EN61000-4-5
Surge current load (surge)​
Input: ± 0.5 kV (DC supply)
Signal: ± 1 kV (Data line, asymmetrical)
Comments: Criterion B
Conducted interference
Standards/regulations: EN61000-4-6
Conducted interference​
Frequency range: 0.15 MHz ... 80 MHz
Comments: Criterion A
Voltage: 10 V
Emitted interference
Standards/regulations: EN55032
Comments: Class A, industrial applications
Criteria
Criterion A: Normal operating behavior within the specified limits.
Criterion B: Temporary impairment to operational behavior that is corrected by the device itself.
Standards and regulationsFree from substances that could impair the application of coating: in accordance with VW-AUDI-Seat central standard P-VW 3.10.7 57 65 0
Electrical isolation: according to IEEE 802.3
MountingMounting type: DIN rail mounting
Technical Specs
ECLASSECLASS-11.0: 19170411
ECLASS-12.0: 19170411
ECLASS-13.0: 19170411
ETIMETIM 9.0: EC001467
UNSPSCUNSPSC 21.0: 43201500
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00056.pdf

Approvals_00057.pdf

Approvals_00127.pdf

Approvals_01290.pdf

Data_sheet_03077.pdf

Data_sheet_03780.pdf

Manufacturer_declaration_00664.pdf

Manufacturer_declaration_05545.pdf

Manufacturer_declaration_15738.pdf

Manufacturer_declaration_17707.pdf

Package_slip_01090.pdf

Technical_drawing_39663.pdf

Various_00003.pdf