Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 2902856
PHOENIX CONTACTNot available

FL MC EF 1300 SM SC - FO converters

FO converter with SC duplex fiber optic connection (1300nm), for converting 10/100Base-T(X) to single mode fiberglass (9/125µm). Auto negotiation and auto MDI(X) function. Comprehensive link diagnostics. DIN-rail mountable, 18...30VDC supply.
Product Code: 2902856
Partner cod.: 2902856
PHOENIX CONTACT


Diminuisci la quantitĂ 
Aumenta la quantitĂ 
Tecnichal data
Technical Specs
Description
Download
Tecnichal data
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Utilization restrictionĂ¢€‹
CCCex note: Use in potentially explosive areas is not permitted in China.
Product propertiesProduct type: Media converter
MTTF: 1400 Years (SN29500 standard, temperature25°C, operating cycle21%)
599 Years (SN29500 standard, temperature40°C, operating cycle34.25%)
101 Years (SN29500 standard, temperature40°C, operating cycle100%)
MTBF: 284 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))
74 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day))
Signal delay: ± 1.3 µs (Store and Forward mode, 10/100 Mbps, depending on the frame size)
System propertiesFunctionality
Basic functions: Store-and-forward media converter
Electrical propertiesElectrical isolation: according to IEEE 802.3
VCC // FE // Ethernet
Maximum power dissipation for nominal condition: 2.4 W
Test voltage data interface/power supply: 0.5 kVrms (50Hz, 1min.)
Supply
Supply voltage range: 18 VDC ... 30 VDC (Screw connection)
18 VDC ... 30 VDC (as an alternative or redundant, via backplane bus contact and system current supply)
Typical current consumption: < 100 mA (24VDC)
Protective circuit: Reverse polarity protection
Connection dataSupply
Connection method: Plug-in screw terminal block (COMBICON), redundancy possible
Single conductor/terminal point, rigid: 0.2 mm² ... 2.5 mm²
Single-wire/terminal point, flexible: 0.2 mm² ... 2.5 mm²
Conductor cross section, flexible [AWG]: 24 ... 14
Tightening torque: 0.56 Nm ... 0.79 Nm
InterfacesSignal: Ethernet
Basic functions: Store-and-forward media converter
Data: optical FO
Transmit capacity, minimum: Ă¢‰¥ -15 dBm ((9/125µm) dynamic in link mode (average))
Transmit capacity, maximum: Ă¢‰¤ -8 dBm ((9/125µm) dynamic in link mode (average))
Transmission length incl. 3 dB system reserve: 36 km (F-E 9/125 0.36dB/km)
32 km (F-E 9/125 0.4dB/km)
26 km (F-E 9/125 0.5dB/km)
Connection method: SC duplex
Wavelength: 1300 nm
Minimum receiver sensitivity: -31 dBm (dynamic in link mode (average))
Maximum receiver sensitivity: -7 dBm (dynamic in link mode (average))
Transmission medium: Single-mode fiberglass
Data: Ethernet interface, 10/100Base-T(X) in accordance with IEEE 802.3
Transmission speed: 10/100 Mbps
Connection method: RJ45 jack, shielded
No. of channels: 1
Transmission length: 100 m (shielded twisted pair)
Transmission medium: Copper
Signal LEDs: Activity, link status, 10/100 Mbps
Auto-negotiation modes: Auto
Link through: Link fault pass through
MDI-/MDI-X switchover: Auto-MDI(X)
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/a676a27eef491e4597eb4a01cc11921e/-S204x204-FJPG
Width: 22.5 mm
Height: 99 mm
Depth: 114.5 mm
Material specificationsMaterial: PA 6.6-FR
Cable/lineFO cable
Fiber types: 50/125 µm
62.5/125 µm
Fiberglass
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -40°C ... 65°C
Ambient temperature (storage/transport): -40°C ... 85°C
Altitude: Ă¢‰¤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation)
Ă¢‰¤ 2000 m (in acc. with UL)
Permissible humidity (operation): 5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport): 5 % ... 95 % (non-condensing)
ApprovalsCE
Certificate: CE-compliant
EAC
Identification: EAC
ATEX
Identification: ĂÂŻÂÂ II 3 G Ex nA IIC T4 Gc X
Note: Please follow the special installation instructions in the documentation!
UL, USA/Canada
Identification: 508 Listed
Class I, Zone 2, AEx nA IIC T4
Class I, Zone 2, Ex nA IIC T4 Gc X
Class I, Div. 2, Groups A, B, C, D
Corrosive gas test
Identification: ISA-S71.04-1985 G3 Harsh Group A
Shipbuilding
Identification: DNV GL
DNV GL data
Temperature: B
Humidity: A
Vibration: A
EMC: B
Enclosure: Required protection according to the Rules shall be provided upon installation on board
EMC dataElectromagnetic compatibility: Conformance with EMC Directive 2014/30/EU
Electrostatic discharge
Standards/regulations: EN61000-4-2
Electrostatic dischargeĂ¢€‹
Contact discharge: ± 6 kV (Test Level 3)
Discharge in air: ± 8 kV (Test Level 3)
Indirect discharge: ± 6 kV
Comments: Criterion B
Electromagnetic HF field
Standards/regulations: EN61000-4-3
Electromagnetic HF fieldĂ¢€‹
Frequency range: 80 MHz ... 3 GHz (Test Level 3)
Field intensity: 10 V/m
Comments: Criterion A
Fast transients (burst)
Standards/regulations: EN61000-4-4
Fast transients (burst)Ă¢€‹
Input: ± 2 kV (Test Level 3)
Signal: ± 2 kV (Test Level 3)
Comments: Criterion B
Surge current load (surge)
Standards/regulations: EN61000-4-5
Surge current load (surge)Ă¢€‹
Input: ± 0.5 kV (DC supply)
Signal: ± 1 kV (Data line, asymmetrical)
Comments: Criterion B
Conducted interference
Standards/regulations: EN61000-4-6
Conducted interferenceĂ¢€‹
Frequency range: 0.15 MHz ... 80 MHz
Comments: Criterion A
Voltage: 10 V
Emitted interference
Standards/regulations: EN55032
Comments: Class A, industrial applications
Criteria
Criterion A: Normal operating behavior within the specified limits.
Criterion B: Temporary impairment to operational behavior that is corrected by the device itself.
Standards and regulationsFree from substances that could impair the application of coating: in accordance with VW-AUDI-Seat central standard P-VW 3.10.7 57 65 0
Electrical isolation: according to IEEE 802.3
MountingMounting type: DIN rail mounting
Technical Specs
ECLASSECLASS-11.0: 19170411
ECLASS-12.0: 19170411
ECLASS-13.0: 19170411
ETIMETIM 9.0: EC001467
UNSPSCUNSPSC 21.0: 43201500
Description
FO converter with SC duplex fiber optic connection (1300 nm), for converting 10/100Base-T(X) to single mode fiberglass (9/125 µm). Auto negotiation and auto MDI(X) function. Comprehensive link diagnostics. DIN-rail mountable, 18 ... 30 V DC supply.
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00056.pdf

Approvals_00057.pdf

Approvals_00121.pdf

Data_sheet_03781.pdf

Data_sheet_03077.pdf

Manufacturer_declaration_04754.pdf

Manufacturer_declaration_05545.pdf

Manufacturer_declaration_15739.pdf

Manufacturer_declaration_17707.pdf

Package_slip_01091.pdf

Technical_drawing_39664.pdf

Various_00003.pdf