PHOENIX CONTACT 2905577
PHOENIX CONTACTNot available

MINI MCR-SL-IDS-I-I - Output signal conditioner

3-way output signal conditioner for transmitting 0/4 ... 20 mA signals from the controller to a load located in the field with simultaneous 3-way electrical isolation between the input, output, and supply, with screw connection
Product Code: 2905577
Partner cod.: 2905577
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Product propertiesProduct type: Repeater power supplies
Product family: MINI Analog
No. of channels: 1
Insulation characteristics
Overvoltage category: II
Pollution degree: 2
Electrical propertiesNo. of channels: 1
Electrical isolation: 3-way isolation
Limit frequency (3 dB): > 175 Hz
Protective circuit: Transient protection
Signal transmission behavior: In=Out
Step response (10-90%): < 2 ms
Maximum temperature coefficient: < 0.01 %/K
Temperature coefficient, typical: < 0.01 %/K
Maximum transmission error: ≤ 0.1 % (of final value)
Electrical isolation Input/output/power supply
Rated insulation voltage: 50 V AC/DC
Test voltage: 1.5 kV AC (50Hz, 60s)
Insulation: Basic insulation in accordance with IEC/EN61010
Supply
Nominal supply voltage: 24 VDC
Supply voltage range: 19.2 VDC ... 30 VDC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN60715)
Power consumption: < 600 mW (at 24 V DC)
Input dataSignal
Number of inputs: 1
Current input signal: 0 mA ... 20 mA
4 mA ... 20 mA
Max. current input signal: 20 mA
Input voltage limitation: < 2 V (20mA)
Output dataSignal: Current
Number of outputs: 1
Current output signal: 0 mA ... 20 mA
4 mA ... 20 mA
Load/output load current output: ≤ 800 Ω (at 20 mA)
Ripple: < 20 mVrms
Connection dataConnection method: Screw connection
Stripping length: 12 mm
Screw thread: M3
Conductor cross section rigid: 0.2 mm² ... 2.5 mm²
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross section AWG: 26 ... 12
InterfacesData communication (bypass)
HART function: Yes
Limit frequency (3 dB): 2.5 Hz
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/8450693c9d67004aa7841c306225c8da/-S204x204-FJPG
Width: 6.2 mm
Height: 93.1 mm
Depth: 101.2 mm
Material specificationsFire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 2
Housing material: PBT
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -20°C ... 60°C
Ambient temperature (storage/transport): -40°C ... 85°C
Altitude: ≤ 2000 m
Permissible humidity (operation): 5 % ... 95 % (non-condensing)
ApprovalsCE
Certificate: CE-compliant
UKCA
Certificate: UKCA-compliant
UL, USA/Canada
Identification: UL508 Listed
Class I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, Group IIC
Shipbuilding approval
Certificate: DNV GL TAA000020N
DNV GL data
Temperature: B
Humidity: B
Vibration: B
EMC: A
Enclosure: Required protection according to the Rules shall be provided upon installation on board
EMC dataNoise immunity: EN 61000-6-2
Note: When being exposed to interference, there may be minimal deviations.
Electromagnetic compatibility: Conformance with EMC directive
Noise emission: EN 61000-6-4
Electrostatic discharge
Standards/regulations: EN61000-4-2
Electrostatic discharge​
Comments: Safety measures must be taken to prevent electrostatic discharge.
Electromagnetic HF field
Designation: Electromagnetic RF field
Standards/regulations: EN61000-4-3
Typical deviation from the measuring range final value: 3 %
Fast transients (burst)
Designation: Fast transients (burst)
Standards/regulations: EN61000-4-4
Typical deviation from the measuring range final value: 3 %
Surge current load (surge)
Standards/regulations: EN61000-4-5
Surge current load (surge)​
Comments: Criterion B
Conducted interference
Designation: Conducted interferences
Standards/regulations: EN61000-4-6
Typical deviation from the measuring range final value: 3 %
Standards and regulationsElectrical isolation: 3-way isolation
MountingMounting type: DIN rail mounting
Assembly instructions: The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715.
Mounting position: any
Technical Specs
ECLASSECLASS-11.0: 27210120
ECLASS-12.0: 27210120
ECLASS-13.0: 27210120
ETIMETIM 9.0: EC002653
UNSPSCUNSPSC 21.0: 39121000
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00056.pdf

Approvals_00057.pdf

Approvals_01328.pdf

Approvals_01329.pdf

Approvals_01943.pdf

Data_sheet_03875.pdf

Manual_00026.pdf

Manufacturer_declaration_02409.pdf

Manufacturer_declaration_04821.pdf

Manufacturer_declaration_16055.pdf

Package_slip_01655.pdf

Product_information_00033.pdf

Product_information_00674.pdf

Technical_drawing_40158.pdf