VAL-US 60/O - Type 2 surge protection device

Surge arresters consisting of base element and protective connector with high-capacity varistor, for mounting on NS 35/7.5, 1-channel
Product Code: 2906279
Partner cod.: 2906279
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
Product propertiesIEC test classification: II
T2
EN type: T2
Type: DIN rail module, two-section, divisible
Product type: Surge protection for NEMA power supply units
Product family: VALVETRAB MS
Number of positions: 1
Surge protection fault message: optical
Insulation characteristics
Pollution degree: 2
Electrical propertiesNominal frequency fN: 50 Hz (60Hz)
Connection dataConnection method: Screw connection
Screw thread: M5
Tightening torque: 3 Nm ... 4.5 Nm (UL)
27 lbf-in. ... 40 lbf-in. (UL)
4.5 Nm
30 lbf-in. (UL)
Stripping length: 16 mm
Conductor cross section flexible min.: 1.5 mm²
Conductor cross section flexible max.: 25 mm²
Conductor cross section, rigid min.: 1.5 mm²
Conductor cross section, rigid max.: 35 mm²
Conductor cross section AWG: 15 ... 2
14 ... 2 (UL)
15 ... 2
14 ... 2 (UL)
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/223151a3e00d8f4a91f665d463f321ae/-S204x204-FJPG
Width: 17.6 mm
Height: 77.1 mm
Depth: 89.2 mm
Material specificationsFlammability rating according to UL 94: V0
Housing material: PBT
Protective circuitMode of protection: L-PEN
(L+) - (L-)
(L-) - PE
(L+) - PE
Direction of action: L-N / L-PEN
Nominal voltage UN: 60 VDC
-48 VDC (RRH)
Nominal frequency fN: 50 Hz (60Hz)
Maximum continuous voltage UC: 75 VAC
100 VDC
Maximum continuous operating voltage UC (L-N): 75 VAC
100 VDC
Maximum continuous operating voltage UC (L-PEN): 75 VAC
100 VDC
Rated load current IL: 80 A
Residual current IPE: ≤ 0.45 mA
Standby power consumption PC: ≤ 35 mVA
Nominal discharge current In (8/20) µs: 15 kA
Nominal discharge current In (8/20) µs (L-N): 15 kA
Nominal discharge current In (8/20) µs (L-PEN): 15 kA
Maximum discharge current Imax (8/20) µs: 40 kA
Maximum discharge current Imax (8/20) µs (L-N): 40 kA
Maximum discharge current Imax (8/20) µs (L-PEN): 40 kA
Short-circuit current rating ISCCR: 25 kA
Voltage protection level Up: ≤ 0.55 kV
Voltage protection level Up (L-N): ≤ 0.55 kV
Voltage protection level Up (L-PEN): ≤ 0.55 kV
Residual voltage Ures: ≤ 0.55 kV (at In)
≤ 0.425 kV (at 10 kA)
≤ 0.325 kV (at 5 kA)
≤ 0.275 kV (at 3kA)
TOV behavior at UT: 100 VAC (5s / withstand mode)
TOV behavior at UT (L-N): 100 VAC (5s / withstand mode)
TOV behavior at UT (L-PEN): 100 VAC (5s / withstand mode)
Response time tA: ≤ 25 ns
Response time tA (L-N): ≤ 25 ns
Response time tA (L-PEN): ≤ 25 ns
Max. backup fuse with V-type through wiring: 80 A AC (gG)
Max. backup fuse with branch wiring: 125 A AC (gG)
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20 (only when all terminal points are used)
IP20
Ambient temperature (operation): -40°C ... 80°C
Ambient temperature (storage/transport): -40°C ... 80°C
Altitude: max. 2000 m
Permissible humidity (operation): 5 % ... 95 %
Shock (operation): 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation): 5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
ApprovalsUL specifications
Maximum continuous operating voltage MCOV: 75 VAC
Maximum continuous operating voltage MCOV (L-N): 75 VAC
Maximum continuous operating voltage MCOV (L-G): 75 VAC
Maximum continuous operating voltage MCOV (L+) - (L-): 100 VDC
Maximum continuous operating voltage MCOV (L+/L-) - G: 100 VDC
Voltage protection rating VPR: 500 V
Voltage protection rating VPR (L-N): 0.5 kV
Voltage protection rating VPR (L+) - (L-): 0.33 kV
Voltage protection rating VPR (L+/L-) -G: 0.33 kV
Nominal discharge current In: 10 kA
Nominal discharge current In (L-N): 10 kA
Nominal discharge current In (L+) - (L-): 10 kA
Nominal discharge current In (L+/L-) - G: 10 kA
Mode of protection: L-L
L-G
(L+) - (L-)
(L+) - G
(L-) - G
Nominal voltage: 60 VDC
Power distribution system: Single phase
Measured limiting voltage MLV: 630 V
Measured limiting voltage MLV (L-N): 630 V
SPD Type: 4CA
UL indicator/remote signaling
Operating voltage: 125 VAC
AC operating current: 1 A AC
UL connection data
Tightening torque: 30 lbf-in.
Conductor cross section AWG: 14 ... 2
Standards and regulationsAir clearances and creepage distances
Standards/regulations: EN61643-11 / UL840
MountingMounting type: DIN rail: 35 mm
Technical Specs
ECLASSECLASS-11.0: 27130805
ECLASS-13.0: 27171202
ETIMETIM 8.0: EC000941
UNSPSCUNSPSC 21.0: 39121600
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00200.pdf

Flyer_00002.pdf

Flyer_00001.pdf

Manufacturer_declaration_00147.pdf

Manufacturer_declaration_02935.pdf

Package_slip_00056.pdf