PHOENIX CONTACT 2910382
PHOENIX CONTACTNot available

VAL-US-347/30/1+1V-FM - Type 1 surge protection device

Surge protective device, two channel with remote indicator contact for 347VAC, 2-wire plus ground.
Product Code: 2910382
Partner cod.: 2910382
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Description
Download
Tecnichal data
Product propertiesIEC test classification: II
T2
EN type: T2
IEC power supply system: TN-S
Type: DIN rail module, two-section, divisible
Distance between live and grounded parts: 5 mm
Product type: Surge protection for NEMA power supply units
Product family: VALVETRAB US
Number of positions: 2
Surge protection fault message: Optical, remote indicator contact
Insulation characteristics
Overvoltage category: III
Pollution degree: 2
Electrical propertiesNominal frequency fN: 50 Hz (60Hz)
Indicator/remote signaling
Connection name: Remote fault indicator contact
Switching function: Changeover contact
Operating voltage: 5 VAC ... 250 VAC
30 VDC
Operating current: 5 mA AC ... 1.5 A AC
1 ADC
Connection dataConnection method: Screw connection
Fork-type cable lug
Screw thread: M5
Tightening torque: 3 Nm (1.5mm² ... 16mm²)
4.5 Nm (25mm²...35mm²)
Stripping length: 16 mm
Conductor cross section flexible: 1.5 mm² ... 25 mm²
1.5 mm² ... 16 mm²
Conductor cross section rigid: 1.5 mm² ... 35 mm²
Conductor cross section AWG: 15 ... 2
Remote fault indicator contact
Connection method: Plug-in/screw connection via COMBICON
Screw thread: M2
Tightening torque: 0.25 Nm
Stripping length: 7 mm
Conductor cross section flexible: 0.14 mm² ... 1.5 mm²
Conductor cross section rigid: 0.14 mm² ... 1.5 mm²
Conductor cross section AWG: 28 ... 16
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/fc65ce1f4ea29a42bfe5c5c9a62b3f88/-S204x204-FJPG
Width: 35.6 mm
Height: 96.8 mm
Depth: 65.7 mm (incl. DIN rail 7.5mm)
Horizontal pitch: 2 Div.
Material specificationsFlammability rating according to UL 94: V-0
CTI value of material: 600
Insulating material: PA 6.6/PBT
Material group: I
Housing material: PA 6.6
PBT
Protective circuitMode of protection: L-N
N-PE
Direction of action: 1L-N & N-GND
Nominal voltage UN: 400VAC (TN-S)
347VAC (TN-S)
Nominal frequency fN: 50 Hz (60Hz)
Maximum continuous voltage UC: 580 VAC
Standby power consumption PC: ≤ 150 mVA
Nominal discharge current In (8/20) µs: 15 kA
Maximum discharge current Imax (8/20) µs: 30 kA
Short-circuit current rating ISCCR: 25 kA
Voltage protection level Up: ≤ 2.5 kV
Residual voltage Ures (L-N): ≤ 2.5 kV (at In)
≤ 2.3 kV (at 10 kA)
≤ 2.1 kV (at 5 kA)
≤ 1.9 kV (at 3kA)
Residual voltage Ures (N-PE): ≤ 2.5 kV (at In)
≤ 2.3 kV (at 10 kA)
≤ 2.1 kV (at 5 kA)
≤ 1.9 kV (at 3kA)
TOV behavior at UT: 690 VAC (5s / withstand mode)
762 VAC (120min / withstand mode)
Max. backup fuse with branch wiring: 125 A (gG)
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20 (only when all terminal points are used)
Ambient temperature (operation): -40°C ... 80°C
Ambient temperature (storage/transport): -40°C ... 80°C
Altitude: ≤ 2000 m (amsl)
Permissible humidity (operation): 5 % ... 95 %
Shock (operation): 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation): 5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
ApprovalsUL specifications
Maximum continuous operating voltage MCOV (L-N): 580 VAC
Maximum continuous operating voltage MCOV (L-G): 750 VAC
Maximum continuous operating voltage MCOV (N-G): 580 VAC
Short-circuit current rating (SCCR): 200 kA
Voltage protection rating VPR (L-N): 2000 V
Voltage protection rating VPR (L-G): 4000 V
Voltage protection rating VPR (N-G): 2000 V
UL type: type 1
Nominal discharge current In: 20 kA
Maximum Surge Current per Phase: 30 kA
Mode of protection: L-N
L-G
N-G
Nominal voltage: 347VAC
400VAC
Power distribution system: Single phase
Nominal frequency: 50/60 Hz
SPD Type: 1
UL indicator/remote signaling
Operating voltage: 125 VAC
AC operating current: 1 A AC
UL connection data
Tightening torque: 30 lbf-in.
Conductor cross section AWG: 14 ... 2
Standards and regulationsAir clearances and creepage distances
Standards/regulations: EN60664-1 / EN61643-11
Standards/specifications: IEC 61643-11
EN61643-11
Note: 2011
2012
MountingMounting type: DIN rail: 35 mm
Technical Specs
ECLASSECLASS-11.0: 27130805
ECLASS-13.0: 27171202
ETIMETIM 8.0: EC000941
UNSPSCUNSPSC 21.0: 39121600
Description
Surge protective device, two channel with remote indicator contact for 347 V AC, 2-wire plus ground.
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Flyer_00001.pdf

Flyer_00002.pdf

Manufacturer_declaration_00147.pdf

Manufacturer_declaration_02935.pdf

Package_slip_00103.pdf

Technical_drawing_40961.pdf