PHOENIX CONTACT 2924281
PHOENIX CONTACT 2924281
PHOENIX CONTACTNot available

MACX MCR-SL-2NAM-T-SP - Isolation amplifier

NAMUR 2-channel signal conditioner for operating proximity sensors and switches. The signals are transmitted to the control level via transistor outputs (passive). Line fault detection, 3-way electrical isolation, SIL 2, Push-in connection.
Product Code: 2924281
Partner cod.: 2924281
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Product propertiesProduct type: Isolating switch transf.
Product family: MACX Analog
Application: Digital IN
No. of channels: 2
Type: Signal conditioners with SIL functional safety
Configuration: DIP switches
Insulation characteristics: GBStandard
Overvoltage category: II
Pollution degree: 2
System propertiesFunctionality
Configuration: DIP switches
Electrical propertiesNo. of channels: 2
Electrical isolation: 3-way isolation
Electrical isolation between input and output: yes
Electrical isolation Input/output
Electrical isolation: 265 V (Peak value in accordance with IEC/EN60079-7)
Electrical isolation Input/output/supply, DIN rail connector
Rated insulation voltage: 300 Vrms
Test voltage: 2.5 kV AC (50Hz, 60s)
Insulation: Safe isolation in accordance with IEC/EN61010-1
Electrical isolation Input/supply, DIN rail connector
Electrical isolation: 265 V (Peak value in accordance with IEC/EN60079-7)
Electrical isolation Output 1/output 2
Rated insulation voltage: 50 Vrms
Test voltage: 1 kV AC (50Hz, 60s)
Insulation: Basic insulation in accordance with IEC/EN61010-1
Supply
Nominal supply voltage: 24 VDC
Supply voltage range: 19.2 VDC ... 30 VDC (24VDC, -20%...+25%)
Max. current consumption: < 34 mA (24VDC)
Power dissipation: ≤ 1000 mW
Power consumption: 0.8 W
Input dataSignal: NAMUR
Number of inputs: 2
Available input sources: NAMUR proximity sensors (IEC/EN60947-5-6)
Floating switch contacts
Switch contacts with resistance circuit
Switching threshold "0" signal current: < 1.2 mA (blocking)
Switching threshold "1" signal, current: > 2.1 mA (conductive)
Short-circuit current: 8 mA
Switching hysteresis: < 0.2 mA
Line fault detection: < 0.05 mA ... 0.35 mA (Line break)
< 100 Ω ... 360 Ω (Short circuit)
Activated /deactivated via DIP switch
Non-load voltage: 8 VDC
Output dataSwitching: Transistor
Output description: passive
Minimum switching voltage: 3 VDC
Maximum switching voltage: 30 VDC
Drop (ΔU): < 1.4 V
Max. switching current: 50 mA (short-circuit-proof)
Min. switching current: 5 mA (short-circuit-proof)
Switching frequency: ≤ 5 kHz
Signal
Number of outputs: 2
Connection dataConnection method: Push-in connection
Stripping length: 8 mm
Conductor cross section rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section flexible: 0.2 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Ex dataEx installation (EPL): Gc
Div.2
InterfacesData
No. of channels: 0
SignalingStatus display: Green LED (supply voltage)
LED yellow (switching state)
Red LED (line errors)
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/d4485e18fd60154ba93005f91a55c68d/-S204x204-FJPG
Width: 12.5 mm
Height: 116 mm
Depth: 113.7 mm
Depth NS35/7,5: 114.5 mm (Snapped onto DIN rail NS35/7,5 in accordance with EN60715)
Material specificationsFlammability rating according to UL 94: V0 (Housing)
Housing material: PA 6.6-FR
CharacteristicsSafety data
Safety Integrity Level (SIL): 2
Safety data​
Safety Integrity Level (SIL): 2
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20 (not assessed by UL)
Ambient temperature (operation): -40°C ... 70°C (Any mounting position)
-40°C ... 70°C (Derating)
Ambient temperature (storage/transport): -40°C ... 85°C
Permissible humidity (operation): 10 % ... 95 % (non-condensing)
Altitude range (≤ 2000 m)
Altitude: ≤ 2000 m (The technical data refers to altitudes ≤2000m above mean sea level. For altitudes >2000m above mean sea level, refer to the data sheet.)
Ambient temperature (operation): -40°C ... 60°C
-40°C ... 70°C (Derating)
Rated insulation voltage: 265 V AC/DC (UIsolation“ec”: Supply,input/output)
Altitude range (≤ 3000 m)
Height range: > 2000 m ... 3000 m
Ambient temperature (operation): -40°C ... 54°C
-40°C ... 63°C (Derating)
Rated insulation voltage: 190 V AC/DC (UIsolation“ec”: Supply,input/output)
Altitude range (≤ 4000 m)
Height range: > 3000 m ... 4000 m
Ambient temperature (operation): -40°C ... 48°C
-40°C ... 56°C (Derating)
Rated insulation voltage: 60 V AC/DC (UIsolation“ec”: Supply,input/output)
Altitude range (≤ 5000 m)
Height range: > 4000 m ... 5000 m
Ambient temperature (operation): -40°C ... 42°C
-40°C ... 49°C (Derating)
Rated insulation voltage: 60 V AC/DC (UIsolation“ec”: Supply,input/output)
ApprovalsCE
Certificate: CE-compliant
Note: and EN61326
ATEX
Identification:  II 3 G Ex ec IIC T4 Gc
Certificate: IBExU 08 ATEX 1100 X
UKCAEx(UKEX)
Identification:  II 3 G Ex ec IIC T4 Gc
Certificate: CML 22UKEX3527X
IECEx
Identification: Ex ec IIC T4 Gc
Certificate: IECEx IBE 08.0005X
CCC/China-Ex
Identification: Ex ec IIC T4 Gc
Certificate: 2022122310115713
UL, USA/Canada
Identification: UL508 Listed
UL 61010 Listed
Class I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, Group IIC T4
Shipbuilding approval
Certificate: DNV GL TAA00000AG
Safety Integrity Level (SIL, IEC 61508)
Identification: 2
INMETRO
Identification: Ex ec IIC T4 Gc
Certificate: DNV 18.0141 X
EACEx
Identification:  2Ex nA IIC T4 Gc
Certificate: BY/112 02.01 TP012 103.01 00078
DNV GL data
Temperature: B
Humidity: B
Vibration: A
EMC: B
Enclosure: Required protection according to the Rules shall be provided upon installation on board
EMC dataNoise immunity: EN 61000-6-2
Electromagnetic compatibility: Conformance with EMC directive
Noise emission: EN 61000-6-4
Electromagnetic HF field
Designation: Electromagnetic RF field
Standards/regulations: EN61000-4-3
Evaluation criterion: A
Fast transients (burst)
Designation: Fast transients (burst)
Standards/regulations: EN61000-4-4
Evaluation criterion: A
Conducted interference
Designation: Conducted interferences
Standards/regulations: EN61000-4-6
Evaluation criterion: A
Standards and regulationsElectrical isolation: 3-way isolation
GBStandard
Standards/regulations: GB3836.1
GB3836.3
MountingMounting type: DIN rail mounting
Technical Specs
ECLASSECLASS-11.0: 27210121
ECLASS-12.0: 27210121
ECLASS-13.0: 27210121
ETIMETIM 9.0: EC001485
UNSPSCUNSPSC 21.0: 39121000
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00183.pdf

Approvals_00056.pdf

Approvals_00057.pdf

Approvals_01144.pdf

Approvals_01150.pdf

Approvals_01172.pdf

Certification_00233.pdf

Certification_00237.pdf

Certification_00253.pdf

Data_sheet_03586.pdf

Manual_00026.pdf

Manufacturer_declaration_00590.pdf

Manufacturer_declaration_01619.pdf

Manufacturer_declaration_16587.pdf

Manufacturer_declaration_17787.pdf

Package_slip_01559.pdf

Technical_drawing_41118.pdf