Input data | AC operation Supply system configuration: Star network (TN, TT, IT (PE)) Nominal input voltage range: 120 VÃAC ... 240 VÃAC Input voltage range: 120 VÃAC ... 240 VÃAC ñ10Ã% Switch-on voltage: > 85 VÃAC Shut-down voltage: < 85 VÃAC Electric strength, max.: ââ°¤ 300 VÃAC 15 s Typical national grid voltage: 120 VÃAC 230 VÃAC Voltage type of supply voltage: AC Inrush current: ââ°¤ 25 A (typical) Inrush current integral (I2t): < 0.5 A2s Inrush current limitation: typ. 25 A (after 1Ãms) AC frequency range: 50 Hz ... 60 Hz ñ10Ã% Frequency range (fN): 50 Hz ... 60 Hz ñ10Ã% Mains buffering time: > 17 ms (120ÃVÃAC) > 17 ms (230 V AC) Current consumption: 2.3 A (120ÃVÃAC) 1.2 A (240ÃVÃAC) Nominal power consumption: 285 VA Protective circuit: Transient surge protection; Varistor Switch-on time: < 1 s Input fuse: 6.3 A (internal (device protection)) Recommended breaker for input protection: 6 A ... 16 A (US/CAN: branch circuit protection <Ã20ÃA) (Characteristic B, C, D, K or comparable) Discharge current to PE: < 3.5 mA
|
Output data | Efficiency: typ. 90 % (120ÃVÃAC) typ. 92 % (230 V AC) Nominal output voltage: 24 VÃDC ñ1Ã% Nominal output current (IN): 10 A Static Boost (IStat.Boost): 12.5 A (UN ïâ³Ã230ÃVÃAC) Derating static boost: >Ã40ðCÃ...Ã50ðC 1Ã%/K>Ã50Ã...Ã60ðC 0.22Ã%/K (UN ïâ³Ã230ÃVÃAC, PStat.Boost = PNÃxÃ1.25) Dynamic Boost (IDyn.Boost): 15 A (5 s) Derating: > 40°C ... 50°C (1Ã%Ã/ÃK) Feedback voltage resistance: ââ°¤ 35 VÃDC Protection against overvoltage at the output (OVP): ââ°¤ 30 VÃDC Control deviation: < 1 % (change in load, static 10 % ... 90 %) < 3 % (Dynamic load change 10 % ... 90 %, 10 Hz) < 0.1 % (change in input voltage ñ10 %) Residual ripple: ââ°¤ 10 mVPP Short-circuit-proof: yes Output power: 240 W 300 W 360 W (5 s) Maximum no-load power dissipation: < 2 W (120ÃVÃAC) < 2 W (230 V AC) Power loss nominal load max.: < 25 W (120ÃVÃAC) < 21 W (230 V AC) Rise time: ââ°¤ 12 ms (UOUT (10 % ... 90 %)) Connection in parallel: yes, for redundancy and increased capacity Connection in series: yes Signal relay 13/14 Default: closed Digital: 30 VÃAC 30 VÃDC 100 mA
|
Connection data | Input Connection method: M12 circular connector Coding: S Type of locking: M12 screw locking Number of positions: 3 Output Connection method: M12 circular connector Coding: L Type of locking: M12 screw locking Number of positions: 5
|
Signaling | Types of signaling: LED Floating signal contact Status display: 2 x green LEDs Signal output: LED status indicator Signalization designation: AC OK Status display: LED Color: green AC OK: ACInÃ>Ã0.45ÃxÃACN (ACNÃ=Ã108ÃVÃAC) Signal output: LED status indicatorââ¬Ã¢¹ Signalization designation: DC OK DC OK: UOUT > 0.9 x UN (UN = 24ÃVÃDC)
|
Electrical properties | Number of phases: 1.00 Insulation voltage input/output: 3 kV AC (type test) 1.5 kV AC (routine test)
|
Product properties | Product type: Power supply Product family: TRIO POWER MTBF (IEC 61709, SN 29500): > 850000 h (25ðC) > 460000 h (40ðC) > 190000 h (60ðC) Insulation characteristics Protection class: I Degree of pollution: 3
|
Dimensions | Item dimensions Width: 136 mm Height: 240 mm Depth: 53 mm Drill hole Diameter: 5.6 mm Installation dimensions Installation distance right/left: 20 mm / 20 mm Installation distance top/bottom: 50 mm / 100 mm
|
Mounting | Mounting type: Wall mounting Assembly instructions: Alignable: 20Ãmm horizontally, 50Ãmm vertically above, 100Ãmm vertically below With protective coating: No
|
Material specifications | Flammability rating according to ULÃ94 (housing / terminal blocks): V0 Housing material: Metal Type of housing: Aluminum (AlMg3)
|
Environmental and real-life conditions | Ambient conditions Degree of protection: IP67 Ambient temperature (operation): -25°C ... 60°C Ambient temperature (storage/transport): -40°C ... 85°C Ambient temperature (start-up type tested): -40°C Maximum altitude: ââ°¤ 4000 m (>Ã2000Ãm, Derating: 10Ã%/1000Ãm) Climatic class: 4K26 (ENÃ60721-3-4) Max. permissible relative humidity (operation): ââ°¤ 100 % (at 25°C, non-condensing) Permissible humidity (operation): ââ°¤ 100 % (at 25°C, non-condensing) Shock: 18 ms, 30g, in each space direction (according to IEC 60068-2-27) Vibration (operation): < 15 Hz, amplitude ñ2.5 mm (according to IEC 60068-2-6) 15 Hz ... 150 Hz, 4g, 90 min.
|
Standards and regulations | Overvoltage category EN 61010-1: IIIÃ(ââ°¤Ã2000Ãm) IIÃ(ââ°¤Ã4000Ãm) Electrical safety Standard designation: Electrical safety Standards/specifications: IEC 61010-1 Protective extra-low voltage Standard designation: Protective extra-low voltage Standards/specifications: IEC 61010-1 (SELV) IEC 61010-2-201 (PELV) Safe isolation Standard designation: Safe isolation Standards/specifications: IEC 61558-2-16 Low-voltage power supplies, DC output Standard designation: Low-voltage power supplies, DC output Standards/specifications: ENÃ61204-3 Safety requirements for electrical equipment for measurement, control, and laboratory use Standard designation: Safety requirements for electrical equipment for measurement, control, and laboratory use Standards/specifications: IEC 61010-1 Limit values for harmonic currents Standard designation: Limit values for harmonic currents Standards/specifications: ENÃ61000-3-2 Degrees of protection provided by enclosures (IP code) Standard designation: Degrees of protection provided by enclosures (IP code) Standards/specifications: EN/IEC 60529
|
Approvals | UL Identification: UL/C-UL Listed ULÃ61010-1 ULââ¬Ã¢¹ Identification: UL/C-UL Listed ULÃ61010-2-201
|
EMC data | Low Voltage Directive: Conformance with Low Voltage Directive 2014/35/EC Interference emission: Interference emission in accordance with ENÃ61000-6-3 (residential and commercial) and ENÃ61000-6-4 (industrial) Noise immunity: Immunity in accordance with ENÃ61000-6-1 (residential), ENÃ61000-6-2 (industrial) Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU Conducted noise emission: ENÃ55016 ENÃ61000-6-3 (Class B) Noise emission: EN 55011 (EN 55022) ENÃ55016 ENÃ61000-6-3 (Class B) Harmonic currents Standards/regulations: ENÃ61000-3-2 ENÃ61000-3-2 (Class A) Electrostatic discharge Standards/regulations: ENÃ61000-4-2 Electrostatic dischargeââ¬Ã¢¹ Contact discharge: 6 kV (Test Level 3) Comments: Criterion A Electromagnetic HF field Standards/regulations: ENÃ61000-4-3 Electromagnetic HF fieldââ¬Ã¢¹ Frequency range: 80 MHz ... 1 GHz 1 GHz ... 2 GHz 2 GHz ... 6 GHz Test field strength: 10 V/m (Test Level 3) Comments: Criterion A Fast transients (burst) Standards/regulations: ENÃ61000-4-4 Fast transients (burst)ââ¬Ã¢¹ Input: 4 kV (Test Level 3 - asymmetrical) Output: 2 kV (Test Level 3 - asymmetrical) Signal: 2 kV (Test Level 3 - asymmetrical) Comments: Criterion A Surge voltage load (surge) Standards/regulations: ENÃ61000-4-5 Input: 2 kV (Test Level 4 - symmetrical) 4 kV (Test Level 4 - asymmetrical) Output: 1 kV (Test Level 3 - symmetrical) 2 kV (Test Level 3 - asymmetrical) Signal: 1 kV (Test Level 2 - asymmetrical) Comments: Criterion A Conducted interference Standards/regulations: ENÃ61000-4-6 Conducted interferenceââ¬Ã¢¹ Input/Output: asymmetrical Frequency range: 0.15 MHz ... 80 MHz Comments: Criterion A Voltage: 10 V (Test Level 3) Voltage dips Standards/regulations: ENÃ61000-4-11 Voltage: 230 VÃAC Frequency: 50 Hz Voltage dip: 70 % 40 % 0 % Number of periods: 25 periods 10 periods 1 period Comments: Criterion A Emitted interference Standards/regulations: ENÃ61000-6-3 Radio interference voltage in acc. with EN 55011: ENÃ55011 (ENÃ55022) ClassÃB, area of application: Industry and residential Emitted radio interference in acc. with EN 55011: EN 55011 (EN 55022) Class B, area of application: Industry and residential Criteria Criterion A: Normal operating behavior within the specified limits. Criterion B: Temporary impairment to operational behavior that is corrected by the device itself. Criterion C: Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
|