STEP-PS/ 1AC/12DC/1.5/FL - Power supply unit

Primary-switched STEP POWER power supply for DIN rail mounting, input: 1-phase, output: 12 V DC/1.5 A
Cod. Articolo: 2868554
Cod. Fornitore: 2868554
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Download
Caratteristiche Tecniche
Input dataAC operation
Nominal input voltage range: 100 VÂAC ... 240 VÂAC
Input voltage range: 85 VÂAC ... 264 VÂAC
95 VÂDC ... 250 VÂDC
Input voltage range AC: 85 VÂAC ... 264 VÂAC
Input voltage range DC: 95 VÂDC ... 250 VÂDC
Voltage type of supply voltage: AC/DC
Inrush current: < 15 A (typical)
Inrush current integral (I2t): < 0.1 A2s
AC frequency range: 45 Hz ... 65 Hz
Frequency range DC: 0 Hz
Mains buffering time: typ. 15 ms (120ÂVÂAC)
typ. 70 ms (230 V AC)
Current consumption: 0.33 A (120ÂVÂAC)
0.18 A (230 V AC)
Nominal power consumption: 37.9 VA
Protective circuit: Transient surge protection; Varistor
Power factor (cos phi): 0.57
Typical response time: < 0.5 s
Input fuse: 1.25 A (slow-blow, internal)
Recommended breaker for input protection: 6 A ... 16 A (Characteristics B, C, D, K)
Output dataEfficiency: > 84 % (for 230 V AC and nominal values)
Output characteristic: U/I
Nominal output voltage: 12 VÂDC ±1Â%
Output current Imax: 2.6 A
Nominal output current (IN): 1.5 A (-25°CÂ...Â55°C)
1.65 A (-25°CÂ...Â40°C permanent)
Derating: 55°C ... 70°C (2.5%/K)
Feedback voltage resistance: ≤ 25 VÂDC
Protection against overvoltage at the output (OVP): < 25 VÂDC
Control deviation: < 1 % (change in load, static 10 % ... 90 %)
< 2 % (change in load, dynamic 10 % ... 90 %)
< 0.1 % (change in input voltage ±10 %)
Residual ripple: < 75 mVPP (20ÂMHz)
Output power: 18 W
Peak switching voltages nominal load: < 10 mVPP (20ÂMHz)
Maximum no-load power dissipation: < 0.4 W
Power loss nominal load max.: < 3.2 W
Rise time: < 0.5 s (UOUT (10 % ... 90 %))
Connection in parallel: yes, for redundancy and increased capacity
Connection in series: yes
Connection dataInput
Connection method: Screw connection
Conductor cross section, rigid min.: 0.2 mm²
Conductor cross section, rigid max.: 2.5 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 2.5 mm²
Conductor cross section AWG min.: 24
Conductor cross section AWG max.: 12
Stripping length: 6.5 mm
Screw thread: M3
Tightening torque, min: 0.5 Nm
Tightening torque max: 0.6 Nm
Output
Connection method: Screw connection
Conductor cross section, rigid min.: 0.2 mm²
Conductor cross section, rigid max.: 2.5 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 2.5 mm²
Conductor cross section AWG min.: 24
Conductor cross section AWG max.: 12
Stripping length: 6.5 mm
Screw thread: M3
Tightening torque, min: 0.5 Nm
Tightening torque max: 0.6 Nm
SignalingTypes of signaling: LED
Operating voltage display: Green LED
Signal output: LED status indicator
Status display: "DC OK" LED green
Note on status display: UOUT > 10.8 V: LED on
Electrical propertiesNumber of phases: 1.00
Insulation voltage input/output: 4 kV AC (type test)
3.75 kV AC (routine test)
3.75 kV AC (routine test)
4 kV AC (type test)
Product propertiesProduct type: Power supply
Product family: STEPÂPOWER
MTBF (IEC 61709, SN 29500): > 1800000 h (40°C)
Insulation characteristics
Protection class: II (in closed control cabinet)
Overvoltage category: III
Degree of pollution: 2
DimensionsWidth: 36 mm
Height: 90 mm
Depth Device depth (DIN rail mounting): 37 mm (Device depth (DIN rail mounting))
Horizontal pitch: 2 Div.
Installation dimensions
Installation distance right/left: 0 mm / 0 mm
Installation distance top/bottom: 30 mm / 30 mm
MountingMounting type: DIN rail mounting
Assembly instructions: alignable: 0Âmm horizontally, 30Âmm vertically
Mounting position: horizontal DIN rail NS 35, EN 60715
With protective coating: No
Material specificationsHousing material: Plastic
Polycarbonate
Foot latch material: POM (Polyoxymethylene)
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -25°C ... 70°C (> 55° C derating : 2.5%/K)
Ambient temperature (storage/transport): -40°C ... 85°C
Climatic class: 3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation): ≤ 95 % (at 25°C, non-condensing)
Shock: 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation): < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 2.3g, 90 min.
Standards and regulationsRail applications: ENÂ50121-4
Budgetary standard: IEC 60335-1
Standard âۉ€œ Electronic equipment for use in electrical power installations and their assembly into electrical power installations: ENÂ50178/VDEÂ0160 (PELV)
Standard âۉ€œ Limitation of mains harmonic currents: ENÂ61000-3-2
Standard - Electrical safety: IEC 62368-1Â(SELV)
Standard - Approval for medical use: IEC 60601-1, 2ÂxÂMOOP
Standard âۉ€œ Protection against shock currents, basic requirements for protective separation in electrical equipment: ENÂ50178
Standard âۉ€œ Safety extra-low voltage: IEC 62368-1 (SELV) und ENÂ60204-1 (PELV)
Standard - Safe isolation: DINÂVDEÂ0100-410
Standard - Safety of transformers: ENÂ61558-2-16
ApprovalsCSA: CSA-C22.2 No.Â107.1-01
Shipbuilding approval: DNVÂGLÂ(EMCÂB)ÂABS, NK
UL approvals: UL/C-UL listed ULÂ508
UL/C-UL Recognized ULÂ60950-1
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location)
NEC Class 2 as per UL 1310
Conformity/Approvals
SIL in accordance with IEC 61508: 0
EMC dataLow Voltage Directive: Conformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise emission: ENÂ61000-6-3
ENÂ61000-6-4
EMC requirements for noise immunity: ENÂ61000-6-1
ENÂ61000-6-2
Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU
Electrostatic discharge
Standards/regulations: ENÂ61000-4-2
Electrostatic dischargeâۉ€¹
Contact discharge: 8 kV (Test Level 4)
Discharge in air: 8 kV (Test Level 3)
Comments: Criterion B
Electromagnetic HF field
Standards/regulations: ENÂ61000-4-3
Electromagnetic HF fieldâۉ€¹
Frequency range: 80 MHz ... 3 GHz
Test field strength: 10 V/m (Test Level 3)
Comments: Criterion A
Fast transients (burst)
Standards/regulations: ENÂ61000-4-4
Fast transients (burst)âۉ€¹
Input: 4 kV (Test Level 4 - asymmetrical)
Output: 2 kV (Test Level 3 - asymmetrical)
Comments: Criterion A
Surge voltage load (surge)
Standards/regulations: ENÂ61000-4-5
Input: 2 kV (Test Level 3 - symmetrical)
4 kV (Test Level 4 - asymmetrical)
Output: 0.5 kV (Test Level 1 - symmetrical)
1 kV (Test Level 2 - asymmetrical)
Comments: Criterion A
Conducted interference
Standards/regulations: ENÂ61000-4-6
Conducted interferenceâۉ€¹
Input/Output: asymmetrical
Frequency range: 10 kHz ... 80 MHz
Comments: Criterion A
Voltage: 10 V (Test Level 3)
Voltage dips
Standards/regulations: ENÂ61000-4-11
Emitted interference
Standards/regulations: ENÂ61000-6-3
Radio interference voltage in acc. with EN 55011: ENÂ55011 (ENÂ55022) classÂB used in industry and residential area / EMCÂ1
Emitted radio interference in acc. with EN 55011: EN 55011 (EN 55022) class B used in industry and residential area / EMC 1
Criteria
Criterion A: Normal operating behavior within the specified limits.
Criterion B: Temporary impairment to operational behavior that is corrected by the device itself.
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00048.pdf

Approvals_00054.pdf

Approvals_00055.pdf

Approvals_00056.pdf

Approvals_00057.pdf

Approvals_00174.pdf

Approvals_00176.pdf

Approvals_00189.pdf

Data_sheet_03672.pdf

Manufacturer_declaration_00496.pdf

Manufacturer_declaration_03011.pdf

Manufacturer_declaration_05504.pdf

Manufacturer_declaration_15358.pdf

Package_slip_02320.pdf

Technical_drawing_39080.pdf

Various_00006.pdf