PHOENIX CONTACT 1190017
PHOENIX CONTACT 1190017
PHOENIX CONTACTAvailable

AXL SE SSDO4/2 2A - Safety module

Axioline SmartElements, Digital output module, Functional safety, SafetyBridge technology, Safe digital outputs:2 (2-channel assignment), 4 (1-channel assignment), 24 VDC, 2 A, connection technology:2-conductor, degree of protection: IP20
Product Code: 1190017
Partner cod.: 1190017
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Download
Tecnichal data
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/9e6e964f367bbe4db818e0ffaa606273/-S204x204-FJPG
Width: 14.9 mm
Height: 62.2 mm
Depth: 62 mm
InterfacesSmartÂElement interface
Number of interfaces: 1
Connection method: Card edge connector
Transmission speed: See system in which you use the SmartÂElement.
System propertiesModule
Input address area: 5 Byte
Output address area: 6 Byte
Output dataDigital
Output name: Safe digital outputs
Output description: ENÂ61131-2
Connection method: Push-in connection
Connection technology: 2-conductor
Number of outputs: 2 (2-channel assignment)
4 (1-channel assignment)
Protective circuit: Short-circuit protection, overload protection of the outputs; electronic
Output voltage: 24 VÂDC
Output current: max. 2 A (per output)
Maximum output current per channel: 2 A
Maximum output current per module: 4 A
Nominal output voltage: 24 VÂDC
Load min.: 1.5 kΩ (at nominal voltage)
Output voltage when switched off: < 5 V
Output current when switched off: < 2 mA
Nominal load, inductive: 48 VA (1ÂH; 12ÂΩ; at nominal voltage)
Nominal load, ohmic: 48 W (12ÂΩ, at nominal voltage)
Switching frequency: 1 Hz (0.2ÂHz at >Â1ÂA)
Reverse voltage resistance to short pulses: no
Behavior with overload: Switch-off of the relevant output, restart upon acknowledgment
Behavior with inductive overload: Output can be destroyed
Product propertiesType: modular
Product type: I/O component
Product family: Axioline SmartÂElements
Mounting position: any
Application: Functional safety
SafetyBridge technology
Operating mode: SafetyBridge
Insulation characteristics
Overvoltage category: II (IEC 60664-1)
Pollution degree: 2 (ENÂ60664-1)
Electrical propertiesPotentials: AxiolineÂF local bus supply (U
Supply voltage: 5 VÂDC (via bus base module)
Current draw: max. 120 mA (at UBus 5ÂVÂDC)
typ. 93 mA (at UBus 5ÂVÂDC)
Potentials: Communications power supply of the Smart Elements (U
Supply voltage: using card edge connectors
Potentials: I/O supply (U
Supply voltage: 24 VÂDC (using card edge connectors)
Supply voltage range: 19.2 VÂDC ... 30 VÂDC (including all tolerances, including ripple)
Current draw: max. 30 mA ((Supply from UP with 30ÂVÂDC, all outputs set, without supply to the actuators))
typ. 25 mA ((Supply from UP with 24ÂVÂDC, all outputs set, without supply to the actuators))
Current consumption: min. 21 mA ((Supply from UP with 19.2ÂVÂDC, all outputs set, without supply to the actuators))
Power consumption: max. 900 mW
min. 403 mW
Connection dataConnection technology
Connection name: I/O
Note on the connection method: Note the specification in the section Conductor cross sections, and stripping and insertion lengths.
Conductor connection
Connection method: Push-in connection
Conductor cross section rigid: 0.25 mm² ... 1.5 mm²
Conductor cross section flexible: 0.25 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Stripping length: 8 mm
I/O
Connection method: Push-in connection
Note on the connection method: Note the specification in the section Conductor cross sections, and stripping and insertion lengths.
Conductor cross section, rigid: 0.25 mm² ... 1.5 mm²
Conductor cross section, flexible: 0.25 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Stripping length: 8 mm
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -25°C ... 60°C
Degree of protection: IP20
Degree of protection at installation location: min. IP54
Air pressure (operation): 70 kPa ... 108 kPa
Air pressure (storage/transport): 66 kPa ... 108 kPa
Ambient temperature (storage/transport): -40°C ... 85°C
Permissible humidity (operation): 5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport): 5 % ... 95 % (non-condensing)
Standards and regulationsProtection class: III (IEC 61140, ENÂ61140, VDEÂ0140-1)
Air clearances and creepage distances
Air clearances and creepage distances: IEC 60664-1
MountingMounting type: Smart Element slot
Mounting position: any
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00183.pdf

Approvals_00523.pdf

Approvals_01798.pdf

Approvals_01799.pdf

Certification_00369.pdf

Manual_00045.pdf

Manual_00088.pdf

Manufacturer_declaration_01310.pdf

Manufacturer_declaration_02313.pdf

Manufacturer_declaration_06733.pdf

Package_slip_00781.pdf

Product_information_00033.pdf

Product_information_00999.pdf

Technical_drawing_09957.pdf