Industrial Automation
PLT-SEC-T3-3S-230-FM - Type 3 surge protection device
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
Product properties | IEC power supply system: TN-S TT Type: DIN rail module, two-section, divisible Product type: Device protection Product family: SEC Family Number of positions: 4 Surge protection fault message: Optical, remote indicator contact Insulation characteristics Overvoltage category: III Pollution degree: 2 IEC test classification: III T3 EN type: T3 Number of ports: One |
Electrical properties | Indicator/remote signaling Connection name: Remote fault indicator contact Switching function: N/C contact Operating voltage: 250 VAC 125 VDC (200 mA DC) Operating current: 3 A AC 1 ADC (30VDC) |
Connection data | Connection method: Screw connection Screw thread: M3 Tightening torque: 0.8 Nm Conductor cross section flexible: 0.2 mm² ... 2.5 mm² Conductor cross section rigid: 0.2 mm² ... 4 mm² Conductor cross section AWG: 24 ... 12 |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/3df01cdb09c09940a4b34a25dfb3b4cc/-S204x204-FJPG Width: 35.4 mm Height: 90 mm Depth: 74.5 mm (incl. DIN rail 7.5mm) Horizontal pitch: 2 Div. |
Material specifications | Flammability rating according to UL 94: V-0 CTI value of material: 600 Insulating material: PA 6.6-FR 20% GF PA 6.6-FR Material group: I Housing material: PA 6.6-FR 20% GF PA 6.6-FR |
Protective circuit | Mode of protection: L-N L-PE N-PE Direction of action: 3L-N & N-PE Nominal voltage UN: 230/400VAC(TN-S) 230/400VAC(TT - only in use with RCD) Nominal frequency fN: 50 Hz (60Hz) Maximum continuous voltage UC: 264 VAC Rated load current IL: 26 A (30°C) Residual current IPE: ⤠5 µA Standby power consumption PC: ⤠2 VA (at UREF) ⤠2.2 VA (at UC) Reference test voltage UREF: 255 VAC Nominal discharge current In (8/20) µs: 3 kA Combination wave UOC: 6 kV Voltage protection level Up (L-N): ⤠1.4 kV Voltage protection level Up (L-PE): ⤠1.5 kV Voltage protection level Up (N-PE): ⤠1.5 kV TOV behavior at UT (L-N): 440 VAC (5s / withstand mode) 440 VAC (120min / withstand mode) TOV behavior at UT (L-PE): 440 VAC (5s / withstand mode) 440 VAC (120min / withstand mode) 1455 VAC (200ms / safe failure mode) TOV behavior at UT (N-PE): 1200 VAC (200ms / safe failure mode) Response time tA (L-N): ⤠25 ns Response time tA (L-PE): ⤠100 ns Response time tA (N-PE): ⤠100 ns Short-circuit current rating ISCCR: 1.5 kA AC Max. backup fuse with branch wiring: not required |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 Ambient temperature (operation): -40°C ... 70°C Ambient temperature (storage/transport): -40°C ... 70°C Altitude: ⤠2000 m (amsl) Permissible humidity (operation): 5 % ... 95 % Shock (operation): 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) Vibration (operation): 5g (10 ... 150 Hz/20 cycles/axis/X, Y, Z) |
Standards and regulations | Standards/specifications: IEC 61643-11 Note: 2011 EN 61643-11 Standards/specifications: EN61643-11 Note: 2012 |
Mounting | Mounting type: DIN rail: 35 mm |
ECLASS | ECLASS-11.0: 27130806 ECLASS-13.0: 27171203 |
ETIM | ETIM 9.0: EC000942 |
UNSPSC | UNSPSC 21.0: 39121600 |
Description other products